File #: 18-2301    Version: 2 Name:
Type: Reports from City Commissions, Committees, and Boards Status: Agenda Ready
File created: 11/14/2018 In control: City Council
On agenda: 12/6/2018 Final action:
Title: City Council consideration of Parcel Map 36667 to subdivide 1.60 acres into four parcels for single-family residential purposes (located at the terminus of Riverbend Circle, generally on the east side of Fullerton Avenue and south of Taber Street) in the Medium Density Residential designation of the Corona Vista Specific Plan (SP90-5). (Applicant: Melvin Aou, Poppybend, LLC)
Attachments: 1. Staff Report.pdf, 2. Staff Report with Attachments.pdf
AGENDA REPORT
REQUEST FOR CITY COUNCIL ACTION



DATE: 12/6/2018

TO: Honorable Mayor and City Council Members

FROM: Community Development Department

SUBJECT:
Title
City Council consideration of Parcel Map 36667 to subdivide 1.60 acres into four parcels for single-family residential purposes (located at the terminus of Riverbend Circle, generally on the east side of Fullerton Avenue and south of Taber Street) in the Medium Density Residential designation of the Corona Vista Specific Plan (SP90-5). (Applicant: Melvin Aou, Poppybend, LLC)

End
RECOMMENDED ACTION:
Recommended action
That the City Council approve PM 36667 subject to the findings and conditions as recommended by the Planning and Housing Commission.

Body
ANALYSIS:
Parcel Map 36667 is a proposal to subdivide 1.60 acres located at the terminus of Riverbend Circle, east of Fullerton Avenue and south of Taber Street into four parcels for the development of four single-family residential homes. The property is located in the Corona Vista Specific Plan (SP90-5) and zoned Medium Density Residential (MDR). The four parcels and the associated roadway improvements adjacent to the project site will complete the existing cul-de-sac on Riverbend Circle. The minimum lot size requirement under the MDR designation is 7,200 square feet. The proposed lots range from 10,621 to 27,498 square feet. The lots are also designed to meet the lot width and lot depth described by the zone which is 65 feet and 80 feet, respectively. Also, the flag lot configuration for Parcel 3 meets the minimum design standard for a flag lot, which is 20,000 square feet with the access corridor of the lot having a depth of at least 80 feet and a width of 25 feet. PM 36667 also proposes two lettered lots which are identified as Lots A and B. Lot A is for the street dedication of Riverbend Circle to complete the cul-de-sac on Riverbend Circle. Lot B is for the construction of sidewalk, utilities, and landscaping located on...